APPLICATION PUMP VOLTAGE RATING FULL LOAD AMPS PUMPING RANGE FLOATS INCLUDED
IFS 1-Phase Simplex Demand/TD Indoor/outdoor simplex (demand/TD)
control system
120/208/240 VAC Up to 20 FLA Depends upon application Sensor Float® control switches
IFS 1-Phase Duplex Demand/TD Indoor/outdoor duplex (demand/TD)
control system
120/208/240 VAC Up to 20 FLA Depends upon application Sensor Float® control switches
IFS 3-Phase Simplex Demand Indoor/outdoor simplex (demand)
control system
208/240/480 VAC Up to 25 FLA Distance between
start & stop float
Sensor Float® control switches
IFS 3-Phase Duplex Demand Indoor/outdoor duplex (demand)
control system
208/240/480 VAC Up to 25 FLA Distance between
start & stop float
Sensor Float® control switches
IFS Simplex Capacitor Indoor/outdoor simplex capacitor start/run
control system
120/208/240 VAC Up to 40 FLA Distance between
start & stop float
Sensor Float® control switches
IFS Duplex Capacitor Indoor/outdoor duplex capacitor start/run
control system
120/208/240 VAC Up to 40 FLA Distance between
start & stop float
Sensor Float® control switches
 
SINGLE PHASE SIMPLEX APPLICATION PUMP VOLTAGE RATING FULL LOAD AMPS PUMPING RANGE FLOATS INCLUDED
Model 111 Indoor/outdoor simplex
control system
120 VAC or
120/208/240 VAC
Up to 20 FLA Distance between start & stop float or range of pump switch Two Sensor Float® control switches or
one pump switch
(mounting clamp version)
Model 115 Indoor/outdoor simplex
control/alarm system
120 VAC alarm circuit
120 VAC or
120/208/240 VAC
Up to 15 FLA Range of
pump switch
One Sensor Float® control switch and
one pump switch
(mounting clamp version)
Model 112 Indoor/outdoor simplex
control/alarm system
120 VAC control/alarm circuit
120 VAC or
120/208/240 VAC
Up to 30 FLA Distance between
start & stop float
Three Sensor Float® control switches
(mounting clamp version)
 
SINGLE PHASE DUPLEX APPLICATION PUMP VOLTAGE RATING FULL LOAD AMPS PUMPING RANGE FLOATS INCLUDED
Model 122 Indoor/outdoor duplex alternating control/alarm system 120 VAC control/alarm circuit. 120 VAC or
120/208/240 VAC
Up to 30 FLA Distance between
start & stop float
Three or four Sensor Float® control switches
(mounting clamp version)
 
THREE PHASE SIMPLEX APPLICATION PUMP VOLTAGE RATING FULL LOAD AMPS PUMPING RANGE FLOATS INCLUDED
Model 312
Includes adjustable overload protection, branch circuit protection, pump disconnect, and 120 VAC control transformer
Indoor/outdoor
three phase simplex
control/alarm system
120 VAC control circuit
Consult Factory
for application
specifications
Up to 25 FLA Distance between
start & stop float
Three Sensor Float®
control switches
(mounting clamp version)
 
THREE PHASE DUPLEX APPLICATION PUMP VOLTAGE RATING FULL LOAD AMPS PUMPING RANGE FLOATS INCLUDED
Model 322
Includes adjustable overload protection, branch circuit, pump disconnect, and 120 VAC control transformer
Indoor/outdoor three phase duplex alternating
control/alarm system
120 VAC control circuit
Consult Factory
for application
specifications
Up to 25 FLA Distance between
start & stop float
Three or four Sensor Float® control switches
(mounting clamp version)
 
CAPACITOR START/RUN APPLICATION PUMP VOLTAGE RATING FULL LOAD AMPS PUMPING RANGE FLOATS INCLUDED
Model SGS
Call Factory for capacitor kit option code and pricing
Indoor/outdoor
single phase simplex
control/alarm system 120 VAC control/alarm circuit
120 VAC or
120/208/240 VAC
Up to 20 FLA Distance between
start & stop float
Three Sensor Float® control switches
(mounting clamp version)
Model 113
Call Factory for capacitor kit option code and pricing
Indoor/outdoor simplex
control/alarm system
120 VAC control/alarm circuit
120 VAC or
120/208/240 VAC
Up to 40 FLA Distance between
start & stop float
Three Sensor Float® control switches
(mounting clamp version)
Model 123
Call Factory for capacitor kit option code and pricing
Indoor/outdoor duplex
control/alarm system
120 VAC control/alarm circuit
120 VAC or
120/208/240 VAC
Up to 40 FLA Distance between
start & stop float
Three or four Sensor Float® control switches
(mounting clamp version)
 
INTRINSICALLY SAFE APPLICATION PUMP VOLTAGE RATING FULL LOAD AMPS PUMPING RANGE FLOATS INCLUDED
Model 114 Single phase simplex control/alarm system with intrinsically safe float circuits 120 VAC or
120/208/240 VAC
Up to 40 FLA Distance between
start & stop float
Three Sensor Float® control switches
Model 124 Single phase duplex alternating control/alarm system with intrinsically safe float circuits 120 VAC or
120/208/240 VAC
Up to 40 FLA Distance between
start & stop float
Three or four Sensor Float® control switches
Model 314 Three phase simplex control/alarm system with intrinsically safe float circuits Consult Factory
for application
specifications
Up to 25 FLA Distance between
start & stop float
Three Sensor Float® control switches
Model 324 Three phase duplex alternating control/alarm system with intrinsically safe float circuits Consult Factory
for application
specifications
Up to 25 FLA Distance between
start & stop float
Three or four Sensor Float® control switches
DRIP IRRIGATION APPLICATION PUMP VOLTAGE RATING FULL LOAD AMPS PUMPING RANGE FLOATS INCLUDED
Model IFS Drip Embedded controller based single phase simplex control/alarm system for subsurface drip irrigation 120 or 230 VAC Up to 15 FLA Dependent on timer settings Four Sensor Float® control switches
Model DP PLC controller based single phase simplex control/alarm system for subsurface drip irrigation 120 or 230 VAC Up to 3015 FLA Dependent on timer settings Four Sensor Float® control switches
TIMED DOSING APPLICATION PUMP VOLTAGE RATING FULL LOAD AMPS PUMPING RANGE FLOATS INCLUDED
Model TD Indoor/outdoor
single phase simplex control/alarm system. Timed dose pump switch control.
120 VAC or
120/208/240 VAC
Up to 20 FLA Dependent on timer settings One SJE PumpMaster® pump switch and one Sensor Float® Mini
control switch
Model DTD Indoor/outdoor
single phase duplex control/alarm system. Timed dose pump switch control.
120 VAC or
120/208/240 VAC
Up to 30 FLA Dependent on timer settings One SJE PumpMaster® pump switch and one Sensor Float® Mini
control switch
Model PS Indoor/outdoor single phase duplex control/alarm system for pump chamber and
sandfilter timed dose control.
120 VAC or
120/208/240 VAC
Up to 20 FLA Pump Chamber:
Dependent on timer settings & pump switch
Sandfilter Chamber:
.75" - 6.5"
Two SJE PumpMaster® pump switches, one SJE PumpMaster® SPDT pump switch and one Sensor Float®
control switch
 
PLUGGER APPLICATION PUMP VOLTAGE RATING FULL LOAD AMPS PUMPING RANGE FLOATS INCLUDED
Model RP Indoor/outdoor single phase simplex control/alarm system. Plug in pump switch control. RP1 =
120 VAC
RP2 =
208/240 VAC
120V up to 15 FLA
208/240V up to 12 FLA
Dependent on pump switch One Sensor Float® control switch and
one pump switch
(mounting clamp version)
JB Plugger Indoor/outdoor enclosure provides convenient wiring connection for pump station applications. 120/208/240 VAC Not applicable Distance between start & stop float or range of pump switch Includes 120V or 208/240V receptacle for pump, pump switch and terminal strip for alarm system connections
PS Patrol® Built-in high water alarm provides convenient location to connect wiring required for 120V or 208/240V pump station application. 9V model available. 120/208/240 VAC Up to 15 FLA Dependent on pump switch Available with mercury or mechanical pump switches and in various cord lengths
 
WATER WELL APPLICATION PUMP VOLTAGE RATING FULL LOAD AMPS PUMPING RANGE FLOATS INCLUDED
Model 126 Single phase duplex alternating water well pump control. 120/208/240 VAC Up to 30 FLA Dependent on pressure switch setting Not applicable

 

STARTER BOXES PHASE AC VOLTAGE FULL LOAD AMPS

SB1

Single phase 240 VAC 32

SB2

Three phase 240 VAC 23-32

SB3

Three phase 208/240/480 VAC 23-32

 

SPECIAL APPLICATIONS DESCRIPTION
VFDC-4000 Controller The VFDC-4000 controller is a microprocessor controlled system which controls up to four VFDs for constant pressure applications. The VFDC-4000 controller monitors the discharge pressure of a pumping system and adjusts the speed of each pump to maintain a constant pressure. The VFDC-4000 controller also features built-in data logging, communication capabilities, and automatic pump alternation functions.
SP6R Level Controller Simple, easy-to-use microprocessor-based controller monitors any 4-20 mA signal.  It has six programmable relay outputs that can be used for control and alarm.  The transducer input zero and span are fully configurable.  A simulation mode allows the user to test the set points and relay operation.  Also available in a NEMA 4X enclosure.  Call for details.
SP6R-LSC Lift Station Controller Simplicity at its best.  This easy-to-use microprocessor-based controller monitors the level in the wet well via a submersible pressure transducer or any other device with a 4-20 mA signal output.  The SP6R-LSC displays level set points, pump run time, pump cycle count and actual level.  In addition, it provides pump alternation and has a simulation feature.  It can be configured for pump down or pump up applications.  Also available in a NEMA 4X enclosure.  Call for details.
Model LSC12 Panel or
Model LSC32 Panel
Single phase or three phase, duplex, transducer based lift station control system for alternating pump control and system monitoring for water and sewage applications. Both models feature the SP6R-LSC lift station controller showcased above.
Engineered Custom
Control Panels
Built specifically for your application, whether a basic or state-of-the-art industrial grade control system. Please call or fax in your specifications for a quote.
Liquid Level
ALARM SYSTEMS
APPLICATION ENCLOSURE VOLTAGE OPTIONS
Tank
Alert® AB
Designed to monitor liquid levels in lift pump chambers, sump pump basins, holding tanks, sewage, effluent filters and water system. NEMA 1
(indoor)
120V 50/60 Hz or 9 VDC battery backup
(battery not included)
Alternate float switches available
Tank
Alert® ABP
Designed to monitor liquid levels in lift pump chambers, sump basins, holding tanks and water systems. NEMA 1
(indoor)
120V 50/60 Hz
or 9 VDC battery backup
(battery not included) 
Two factory-spliced SJE MilliAmpMaster® control switches
Tank
Alert® I
Designed to monitor liquid levels in lift pump chambers, sump basins, holding tanks and water systems. NEMA 1
(indoor)
120V 50/60 Hz or
230V 50/60 Hz
Alternate float switches available
Tank
Alert® XT

(Includes Alarm Auto Reset)
Designed to monitor liquid levels in lift pump chambers, sump basins, holding tanks and water systems. Meets Type 3R water-tight standard 120V 50/60 Hz Alternate float switches available, alarm auxiliary contacts, terminal block, 6' power cord
Tank
Alert® 4X

(Includes Alarm Auto Reset)
Designed to monitor liquid levels in lift pump chambers, sump basins, holding tanks and water systems. NEMA 4
(indoor/outdoor)
120V 50/60 Hz Alternate float switches available, alarm auxiliary
contacts
 
Wide-Angle
PUMP SWITCHES
APPLICATION HP RATINGS START AMPS RUN AMPS PUMPING RANGE
Junior Super Single®
(mercury activated)
Provides automatic pump operation
in sump, sewage and non-potable
water applications.
1/2 HP at 120V
1 HP at 230V
40 (120V)/13
20 (230V)/8
6.5 to 19 inches
Super Single®
(mercury activated)
Provides automatic pump operation for sump and sewage pumps, solenoids and relays. Not sensitive to rotation/turbulence. 1 HP at 120V
2 HP at 230V
55 (120V)/15
35 (230V)/12
6.5 to 13.5 inches
Double Float®
(mercury activated)
Provides automatic pump operation for sump and sewage pumps, solenoids and relays. Not sensitive to rotation/turbulence. 1 HP at 120V
2 HP at 230V
55 (120V)/15
35 (230V)/12
1.75 to 48 inches
wider ranges available
Double Float® Master
(mechanically activated)
Provides automatic pump operation in potable water and sewage applications. Not sensitive to rotation/turbulence. N/A 78/13 (120V or 240V) 10 to 56 inches up to 6 feet available
SJE PumpMaster®
(mechanically activated)
Provides automatic pump operation in potable water and sewage applications. Not sensitive to rotation/turbulence. 1/2 HP at 120V
1 HP at 230V
85 (120V)/13
85 (230V)/13
7 to 36 inches
SJE PumpMaster® Plus
(mechanically activated)
Provides automatic pump operation in potable water and sewage applications. Not sensitive to rotation/turbulence. 3/4 HP at 120V
2 HP at 230V
85 (120V)/15
85 (230V)/15
7 to 36 inches
SJE PumpMaster® SPDT
(mechanically activated)
Can be wired to provide automatic pump up or pump down operation in potable water and sewage applications. 1/2 HP at 120V
1 HP at 230V
85 (120V)/13
85 (230V)/13
7 to 36 inches
SJE AmpMaster®
(mechanically activated)
Provides automatic control of grinder and high head sewage pumps. 1 1/2 HP at 125V
3 HP at 250V
120 (125V)/20
120 (250V)/20
9 to 24 inches
SJE VerticalMaster®
(mechanically activated)
Provides automatic pump operation
in confined areas. For water and
sump applications.
1/2 HP at 120V
1 HP at 230V
60 (120V)/13
60 (230V)/12
.75 to 6.5 inches
SJE D-Master™
(pressure-actuated)
Provides automatic pump operation
in confined areas. For
sump applications.
1/2 HP at 120V
78/13
10 inches
 
Narrow-Angle
CONTROL SWITCHES
APPLICATIONS CONTROL DIFFERENTIAL ELECTRICAL RATING MOUNTING OPTIONS
Sensor Float®
(mercury activated)
Activates alarms, control panels,
solenoids and relays.
Approximately .5
inch above or
below horizontal
5 amp
120V or 230V
Mounting Clamp
Internal Weight
Cable Weight
Sensor Float® Mini
(mercury activated)
Activates alarms, control panels,
solenoids and relays.
Approximately .5
inch above or
below horizontal
5 amp
120V or 230V
Mounting Clamp
Cable Weight
SJE SignalMaster®
(mechanically activated)
Activates alarms, control panels,
solenoids and relays.
Approximately 1.5
inch above or
below horizontal
5 amp
125V or 250V
Mounting Clamp
Cable Weight
SJE SignalMaster® SPDT
(mechanically activated)
Activates alarms, control panels,
solenoids and relays.
Approximately 1.5
inch above or
below horizontal
5 amp
125V or 250V
Mounting Clamp
Cable Weight
SJE MilliAmpMaster™
(mechanically activated)
Activates low current alarms, and control panels. 45 degrees above or
below horizontal
Down to 0.160mA at 125 VAC Mounting Clamp
Cable Weight
 
ACCESSORIES APPLICATION ENCLOSURE OPTIONS
Junction Boxes Provides convenient location to connect all wiring required for a typical pumping station, on-site system or other electrical installations. NEMA 4X
(indoor/outdoor)
Sizes include:
4" x 4" x 4",
6"x 6" x 4"
8" x 8" x 4"
Cable Weight Provides an accurate pivot point for
suspended float switches.
Cable Connectors Provides strain relief and a liquid-tight seal
for electrical cable.
Round or flat connectors available 
Hub Assembly Convenient connector for a conduit run. 1", 1.5" and 2" sizes
available
Cord Seal Provides strain relief and a liquid-tight seal.
Cable Clamp
Assembly
Secures cable in a vertical direction and provides cable anchor point and strain relief. For use with 18/16 gauge, 14 gauge, or 12 gauge cable
Float Bracket Provides a convenient location for securing both internally and externally weighted floats.  Six or four float bracket available