Model 322 Control Panel Specifications Download Model 322 Control Panel Engineering Specs Document (rtf format)
B. The motor control panel shall be assembled and tested by a controls system manufacturer (SJE-Rhombus or pre-approved equal) meeting the Standards of UL 508A for industrial controls and be UL labeled and serialized accordingly. The motor control panel shall be assembled and tested by the manufacturer so as to insure suitability in matching controls to motors and to insure single source responsibility for the equipment. C. The panel shall contain all components required by the pump manufacturer for starting and protecting the motor as well as features required by the pump manufacturer for warranty of the pumps. Items such as thermal overload detection or seal failure detection shall be included when required. D. Incoming pump power shall be three-phase, 60 Hz, 208/240/480 volts AC. E. The control panel shall incorporate three (3) or four (4) normally open mercury or mechanically-activated control switches with pipe clamps. Floats shall be labeled in the panel as stop, lead, lag/alarm, and alarm. Floats shall be SJE-Rhombus control switches or approved equal. 2.01 CONSTRUCTION B. A nameplate shall be permanently affixed to the panel. A ratings label shall include the model number, voltage, phase, frequency, ampere rating and horsepower rating and shall be affixed to the inside of the enclosure. A warning label against electric shock shall be permanently affixed to the outer door. The interior of the enclosure shall have a clear envelope with "as built" schematics located within. C. A removable aluminum back plate shall be provided for mounting all circuit breakers, motor starters, etc. All components mounted to the back plate shall be secured by type 25, self-tapping screws in extruded holes. Rivets shall not be acceptable for securing any component to the backplate. D. A duplex pump controller shall be provided for control logic. The controller shall utilize a printed circuit board to avoid conventional wiring. The printed circuit board of the pump controller shall be manufactured using U.L. listed materials. There shall be separately fused control and alarm circuit protection. The pump controller shall indicate control and alarm power utilizing an LED indicator light. The pump controller shall indicate float circuit operation utilizing red LED indicator lights. Indicator lights shall provide adequate information so that they can be used for diagnosis in troubleshooting problems located in the float circuits. Each LED shall be permanently labeled on the pump controller as to the function. For each pump a run light and hand-off-auto switch shall be provided. Run lights and hand-off-auto switches shall be mounted on the printed circuit board. Run lights shall be green. E. The magnetic motor starters shall be IEC rated for the pump horsepower and include a contactor with a minimum mechanical life of 5,000,000 operations and a minimum contact life of 1,000,000 operations. A motor protective switch shall be used to provide adjustable overload protection, protect from line faults and disconnect the pump from the incoming power. Motor protective switches shall be adjustable to meet NEC requirements for motor controls. F. A high-level alarm condition shall activate the main alarm light (red, mounted on the top of the panel) and alarm horn. The alarm light shall remain illuminated until the problem is corrected. The alarm horn shall be rated 83-85 dB minimum. A Test-Normal-Silence toggle switch, labeled and placed adjacent to the horn shall be included. G. Control/Alarm voltage shall be 120 VAC and shall be accomplished by the means of a transformer with primary and secondary fusing. H. Wire ties shall be used to maintain panel wiring in neat bundles for maintenance and to prevent interference with operating devices. All grounding conductors shall be securely connected to assure a proper ground. I. The alternator shall consist of an alternating circuit which alternately switches pumps upon the next pumping cycle. The alternation circuitry shall be integrated into the pump controller. J. Provide pump run elapsed time meters for each pump. Run time meters shall be non-resetable and record up to 99,999 hours to the nearest tenth or hundredth. K. The control panel shall be a 322 series panel as manufactured by SJE-Rhombus or approved equal. |